Section 05 ELECTRICAL SYSTEM Subsection 04 (CHARGING SYSTEM) Voltage Regulator/Rectifier Installation Installation is the reverse of removal procedure. However, pay attention to the following. Lock voltage regulator/rectifier in position. Wiggle it to make sure it is safely locked. NOTE: “Key Off” or parasitic loads may be loads due to installed accessories. Parasitic loads may also be due to water infiltration in connectors, or partial short circuits that slowly drain a battery without causing a fuse to burn. NOTE: A battery that continually necessitates the addition of distilled water indicates an over voltage situation. Carry out a CHARGING SYSTEM VOLT- AGE TEST.
Battery Vent and Check Valve WARNING Battery caps do not have vent holes. Ensure vent line is not obstructed and check valve is functioning properly. Check vent line condition. smr2009-033-006_b 1. Locked here Reinstall remaining removed components. BATTERY Troubleshooting smr2009-033-009_b 1. Vent line Make sure that grommet of check valve is not plugged. Disconnect vent hose from battery. smr2009-033-009_a 1. Disconnect here smr2009-033 301 SYMPTOM: DISCHARGED OR WEAK BATTERY CAUSE REMEDY Battery posts and/or cable terminal oxidized. Clean battery terminals, posts, and coat with dielectric grease. Loose or bad connections. Check for wiring and connector tightness, frayed or broken wires.
Repair or replace cables or connectors. Faulty battery (sulfated, fretting, shorted plates or cell, damaged casing, loose post). Replace battery. Burnt fuse(s) or faulty rectifier. First check fuse(s). If in good condition, check voltage regulator/rectifier. Faulty stator. Test stator and replace as required. Parasitic or “Key Off” current loads. Isolate, reduce or eliminate such loads, recharge battery as recommended if vehicle is not used for extended periods of time.