Section 05 ELECTRICAL SYSTEM Subsection 04 (CHARGING SYSTEM) WARNING Failure to remove the sealing tube could re- sult in an explosion. 1 1. Remove caps and fill battery to UPPER LEVEL line with electrolyte (specific gravity: 1.265 at 21°C (70°F)). NOTE: This battery may fill slower than others due to the anti-spill check ball design. 2 A17E0RB 2 1. Battery electrolyte 2. Upper level line 4. Connect a 2 A battery charger for 3 to 5 hours. 3 1 ) * A17E0FB 1. Sealing tube removed 2. Battery electrolyte 3. Upper level line NOTE: Place the cell caps over the cell openings engaging only the first thread to prevent cell contamination and acid splatter during charging.
Do not screw caps on tightly . 2. Allow the battery to stand for 30 minutes MIN- IMUM to allow the electrolyte time to soak through the battery cells plates. Step 1: Connect + lead to battery + post Step 2: Connect - lead to battery - post Step 3: Connect battery charger to AC outlet WARNING Gases given off by a battery being charged are highly explosive. Always charge in a well ventilated area. Keep battery away from cig- arettes, open flames, welding operations and any other types of ignition. Always turn bat- tery charger off prior to disconnecting cables. Otherwise a spark will occur possibly causing the battery to explode.
NOTICE If charging rate increases above 2.4 A reduce it immediately. If cell tempera- ture rises above 50°C (122°F) or if the casing feels hot, discontinue charging temporarily or reduce the charging rate. 1. 30 minutes 5. Disconnect battery charger. 3. Readjust the electrolyte level to the UPPER LEVEL line. 308 smr2009-033