Section 05 ELECTRICAL SYSTEM Subsection 05 (STARTING SYSTEM) smr2009-030-033_f smr2009-030-033_g If test succeeded, the circuit is functional. If test failed, repair wiring/connectors. If test succeeded, circuit is functional. If test failed, repair harness/connectors. Start/Stop Switch Control Circuit Test Keep the same test setup as for the START/STOP SWITCH OPERATION TEST. Disconnect the B connector from ECM. Install ECM ADAPTER TOOL (P/N 529 036 166) on ECM connector. STARTER SOLENOID Solenoid is located below fuse box 2. Use the FLUKE 115 MULTIMETER (P/N 529 035 868) and select . Test continuity of the circuit as per following table. 529036166 smr2009-034-002_b 1. Fuse box 2 2.
Solenoid To reach the solenoid, detach fuse box 2 from its rack. Move fuse box aside to gain access. smr2009-034 317 POWER CIRCUIT TEST 8-PIN CONNECTOR OF DIAGNOSTIC HARNESS FUSE BOX 2 RESISTANCE Pin 2 Terminal B2 Close to 0 (continuity) CONTROL CIRCUIT TEST 8-PIN CONNECTOR OF DIAGNOSTIC HARNESS ECM CONNECTOR B RESISTANCE Pin 1 B-D1 Close to 0 (continuity)