Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 05 ELECTRICAL SYSTEM Subsection 07 (GAUGE) smr2009-036-011_b 1. Read Data button 2. Vehicle page tab 3. Total Hours 4. Supercharger maintenance hours (approximate time left) smr2009-036-011_c 1. Reset Supercharger maintenance button NOTE: Replacement information centers are de- livered already programmed. After the information center has been replaced, connect the watercraft to the latest applicable B.U.D.S. software and carry out any updates (if required). Refer to COMMUNICATION TOOLS AND B.U.D.S. SOFTWARE subsection.

Once the information center has been updated (if required), select the applicable settings as de- scribed in SETTING LANGUAGE AND UNITS OF MEASUREMENT in this subsection. 4. Add the approximate time left to supercharger maintenance hours to the total hours to calcu- late the hours at which the next supercharger maintenance is due. Example: 104.08 + 95.52 = 200 The next supercharger maintenance will be due at 200 hours (Total Hours in B.U.D.S or hours indi- cated in the information center hour meter). 5.

Advise customer to bring the watercraft in for supercharger maintenance at the calculated "Total Hours" even if the supercharger mainte- nance advisory message did not come on in the information center. If the "approximate time left to Supercharger maintenance" hours cannot be retrieved in B.U.D.S. (because old cluster cannot be read by B.U.D.S.), and the engine hours (Total Hours) at which the last supercharger maintenance was carried out are known, then add 100 to the last known Total Hours at which the last supercharger maintenance was carried out.

Once the supercharger maintenance has been carried out, the time left to supercharger main- tenance must be reset using the Reset Super- charger Maintenance function in B.U.D.S. This ensures the following supercharger maintenance advisory message comes on as per normal in- tervals. Refer to CLEARING MAINTENANCE REMINDER INDICATORS in this subsection. MODE/SET AND UP/DOWN ARROW BUTTONS Overview The MODE/SET and UP/DOWN arrow buttons assembly contains a series of 4 diodes for the MODE and SET switches, and another 4 diodes for the UP/DOWN arrow switches. Refer to WIRING DIAGRAM.

The center wire to the switches (pin C), is com- mon to both sides of the switch assembly (some- what like a ground wire). The other two wires (pins A and B), act as signal wires for each set of switches to the information center. They actually each form one branch of an electronic circuit within the information center. Each diode (in circuit) drops a nominal 0.6 Vdc when conducting electricity. If the circuit current passes through all four diodes (say MODE and SET switches open), a drop of 2.4 Vdc would be measured across the 4 the diodes (pin B to pin C). This 2.4 Vdc at pin B tells the gauge the MODE and SET switches are open. smr2009-036 351