Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 05 ELECTRICAL SYSTEM Subsection 07 (GAUGE) DEPTH SOUNDER Depth Sounder Removal 1. Open the boarding platform. GTX Limited iS Models Depth Sounder Troubleshooting ssi2009-002-002_a 1. Re-boarding platform 2. Remove the starboard (RH) storage bin. ssi2009-002-003_a 1. Starboard storage bin 3. Disconnect the diagnostic connector from its holder. ssi2009-002-004_a 1. Diagnostic connector 4. Remove the electrical component support from the battery holder, refer to CHARGING SYS- TEM. smr2009-027-011_c 1. Depth sounder 3A fuse (FB1) smr2009-036 355 DEPTH SOUNDER TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Nothing is displayed in the information center Depth sounder not connected.

Properly connect depth sounder. Depth sounder not properly installed. Make sure depth sounder is properly installed in battery holder base. There must be no air gap between hull and gel pad(s). 12 Vdc wire or ground wire to depth sounder open. Check fuse 3 in FB1 and wiring harnesses. Problem with communication link wires. Check WHITE/BLACK and WHITE/RED wires to CAN bus-bars in FB1. - - - - (ft or m) is displayed Watercraft is not in water. Launch watercraft in water and recheck. There is air between gel pad and depth sounder or between depth sounder and battery holder base. Remove depth sounder. Replace gel pad. Depth sounder is defective. Try a new depth sounder.