Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 06 STEERING AND PROPULSION Subsection 02 (iBR AND VTS) Test With Watercraft on a Waterway 1. Start watercraft and allow engine to run at idle RPM. NOTE: If iBR gate is not in the neutral position be- fore the engine start, it will move to the neutral position on engine start up. 2. Depress the throttle lever slightly, then release it. Forward movement of the watercraft con- firms the iBR gate has moved to the forward position. 3. Depress the iBR lever fully. Rearward move- ment of the watercraft confirms the iBR gate has moved to the reverse position. 4. Release the iBR lever completely. Reverse thrust should cease and the watercraft should continue to drift rearward on momentum. 5.

Apply a small amount of forward thrust to stop rearward velocity, then tap the iBR lever to re- turn the iBR gate to neutral. 6. Shut engine off. 4. Pull in and release the iBR lever to engage for- ward thrust, allow to run at idle RPM 5. Push the VTS up and down arrow button alter- nately to check VTS operation. Confirm nozzle movement and VTS position indication change in the information center. 6. Double click the VTS UP and DOWN button al- ternately to test the VTS preset trim positions.

If double clicking the VTS UP and DOWN button does not cause the nozzle position or indication to change, navigate to VTS MODE function in the gauge and check for recorded PRESET 1 and PRE- SET 2 settings. If no presets are recorded, record PRESET 1 bow up and PRESET 2 bow down, exit the function, a carry out a new test. If both PRESET 1 and PRESET 2 have the same setting, note the operator's setting and change one PRESET, exit the function, and carry out a new test. Return the setting to the operator's preference after testing is complete. NOTE: The VTS system cannot be tested without the engine operating in forward thrust.

If the en- gine is not running in forward thrust, only the VTS indication will change when the VTS control but- ton is pressed; the nozzle will not change position until forward thrust is engaged by pulling the throt- tle lever. VTS FUNCTIONAL TEST NOTE: This test requires two people. One person to start watercraft and operate controls, and one person to observe iBR gate movement. 1. Provide adequate ventilation of exhaust gases or move watercraft outside. NOTICE Do not install an exhaust ventilation hose in the iBR gate area or damage may oc- cur when the iBR gate moves downward dur- ing operation. TROUBLESHOOTING The iBR system is self monitoring.

If a fault oc- curs in the iBR system, it will raise a fault code and communicate it to the information center through the CAN bus. The information center will turn on the iBR indicator light to advise the operator of the iBR system fault. If the fault remains active, it may be displayed in the gauge. If it becomes oc- curred, B.U.D.S. must be used to read the fault. 2. Connect a water hose to the watercraft to pro- vide exhaust system cooling when operating engine. Refer to EXHAUST SYSTEM subsec- tion for procedure. NOTICE Ensure there are no tools or other object that may interfere with the iBR gate movement. Do not run watercraft for more than 2 min- utes out of water or damage may occur.

TESTING SEQUENCE To troubleshoot the iBR system, carry out the fol- lowing in this order: Ensure the iBR gate movement is not ob- structed in any way. Ensure the iBR gate mechanisms (gate, VTS ring, "U" arm and linkages) are all in good condi- tion and do not show signs of excessive wear or friction. Cycle the iBR gate up and down using the iBR OVERRIDE function as described in this sub- section. WARNING The person observing the iBR gate move- ment must stand to the side of the stern well clear of the iBR gate and pump nozzle, and in full view of the operator. 3. Start watercraft. 382 smr2009-037