Section 06 STEERING AND PROPULSION Subsection 02 (iBR AND VTS) smr2009-038-030_a 1. iBR motor harness connector 2. iBR motor module connector smr2009-038-033_b Step 1: Note iBR current draw Step 2: Note iBR position indication change 2. Set the FLUKE 115 MULTIMETER (P/N 529 035 868) to Vdc selection. 3. Install insulated clips on the multimeter leads and clip leads to pins in the motor connector on the iBR module. If current draw is abnormally high (between 20 and 30 A), check the following: Ensure iBR gate is free of debris. Remove iBR gate key and check for excessive friction in gate movement. Check iBR gate friction sleeves and bushings.

Check for proper voltage to the iBR motor, see iBR MOTOR VOLTAGE TEST in this subsection Check for fault codes using B.U.D.S. Remove debris, replace iBR gate components, or replace the iBR actuator as applicable. smr2009-038-031_a TEST OF iBR MODULE OUTPUT VDC TO iBR MOTOR iBR Motor Voltage Test 1. Disconnect the iBR actuator motor connector from the electronic module on the actuator. 4. Using the iBR override function (see SYSTEM DESCRIPTION (iBR in this subsection), press the VTS UP button and read the iBR module motor output voltage. NOTE: The iBR UP button on the iBR Activation page in B.U.D.S. may be used instead of the iBR override function.

smr2009-037 389 iBR ACTUATOR CURRENT DRAW DOWN SELECTION -5 to -15 A UP SELECTION +10 to +20 A