Section 06 STEERING AND PROPULSION Subsection 02 (iBR AND VTS) 5. Depress and hold the VTS UP arrow button and ensure the iBR gate moves up to the forward position. NOTE: If the VTS button is released before full travel of the iBR gate, movement of the iBR gate will cease. If the iBR does not respond to VTS button com- mands (UP or DOWN), carry out the following VTS SWITCH TEST USING B.U.D.S. smr2009-041-051_b 1. VTS UP and VTS Down indicator lights VTS Control Button Test Using B.U.D.S. 1. Connect watercraft to the latest B.U.D.S. soft- ware, refer to COMMUNICATION TOOLS AND B.U.D.S. SOFTWARE. 2. Select the Read Data button. 3. Check for an applicable fault code on the FAULTS page. 4.
Select the Monitoring page tab. 5. In the lower LH corner of the monitoring page, select the Cluster tab. 6. Press the VTS UP arrow and DOWN arrow but- ton alternately and look for the VTS UP and VTS Down indicator lights to come on in the Cluster Lamp Active field. If each of the gauge button indicator lights come on when the applicable switch is closed, the VTS control button switches and wiring are good. The problem may be related to the information center or iBR module. If one or all of the indicator lights do not come on, refer to VTS CONTROL BUTTON TEST USING A MULTIMETER. VTS Control Button Test Using a Multimeter 1. Remove the gauge support cover, refer to GAUGE subsection. 2.
Disconnect the gauge connector. NOTICE Pull connector lock out. Do not twist the screwdriver. smr2009-036-002_c 1. Read Data button 2. Monitoring tab 3. Cluster tab 4. Cluster Lamp Active field smr2009-042-002_a 1. Gauge connector 2. Pull out to unlock connector 3. Use a FLUKE 115 MULTIMETER (P/N 529 035 868) set to the diode test function. Test the VTS but- ton switches as per following tables. NOTE: It is important to set the multimeter to the diode check function when testing the VTS control switches. 404 smr2009-037