Section 06 STEERING AND PROPULSION Subsection 03 (JET PUMP) 5290218002 smr2009-006-008_a TYPICAL MEASURING IMPELLER SHAFT RADIAL PLAY 1. Dial gauge 2. Measure close to impeller hub end RADIAL PLAY 0 mm (0 in) Excessive play can come either from worn bearing or damaged jet pump housing bearing surface. LEAK TEST Whenever performing any type of repair on the jet pump, a leak test should be carry out. Proceed as follows: 1. Remove impeller cover. Refer to IMPELLER COVER in this subsection. 2. Install the PRESSURE CAP (P/N 529 036 172) on pump housing. smr2008-029-005 TYPICAL 4. Pressurize pump. LEAK TEST PRESSURE Maximum 70 kPa (10 PSI) 5.
Pump must maintain this pressure for at least 5 minutes. NOTICE Repair any leak. Failure to correct a leak will lead to premature wear of pump com- ponents. NOTE: If there is a pressure drop, spray soapy water around cover. If there are no bubbles, im- peller shaft, impeller shaft seal, or jet pump hous- ing is leaking through porosity and has to be re- placed. Jet pump unit has to be disassembled. NOTE: There may be 2 or 3 bubbles coming out from the seal on the impeller side. This small leak is acceptable. Leaks from other areas must be re- paired. 529036172 3. Connect the VACUUM/PRESSURE PUMP (P/N 529 021 800) to the pressure cap fitting. 410 smr2009-039