Section 07 BODY AND HULL Subsection 01 (SUSPENSION (iS)) Hydraulic Pump Fluid Level Verification NOTE: The fluid level will drop slightly during break-in period because the actuator uses a small amount of fluid to lubricate its moving parts. If a large amount of fluid is required, check compo- nents for leaks. Reservoir in Vehicle Place the vehicle level (longitudinally and transver- sally). Make sure suspension is in DOCK MODE position. The fluid should be near reservoir plug. NOTE: Remember that each diode should drop approximately 0.6 Vdc when positively biassed, and read as an OL (open circuit) when negatively biassed (leads reversed).
If, when measuring between pins 14 and 15 an OL is obtained with both positive and negative diode biassing, test the wiring harness continu- ity between the gauge and switch assembly. If harness continuity is good, replace the switch assembly. If any reading is significantly different than listed, carry out the same test at the switch connector, refer to the wiring diagram. If you obtain the same results, replace the switch assembly. If voltages measured on every switch are as listed in the previous tables (or very close to it), the switches and the wiring harness are good. The fault may be within the gauge, or in the circuit or component the function applies to. smr2009-041-043_a 1.
Fluid level Reservoir Out of Vehicle Place the reservoir vertically. Using a ruler, measure the fluid level. The reservoir is full when fluid level reaches 130 mm ± 5 mm (5-1/8 in ± 13/64 in). HYDRAULIC PUMP Hydraulic Pump Recommended Fluid Always use automatic transmission fluid (ATF) Dexron III. NOTICE To avoid serious damage to hy- draulic pump and actuator, use only ATF Dexron III. Do not use fluids other than the recommended one, nor mix different types of fluids for topping up. smr2009-041-044_a A. 130 mm ± 5 mm (5-1/8 in ± 13/64 in) To Add Fluid Remove the plug on the end of reservoir. Using a syringe, fill up the reservoir to the recom- mended level.
smr2009-041 453 iS SWITCH TEST SWITCH POSITION MULTIMETER LEAD/GAUGE CONNECTOR VOLTAGE Switch released RED lead/Pin 14 BLACK lead/Pin 15 Approx. 2 Vdc BLACK lead/Pin 14 Red lead/Pin 15 OL UP depressed RED lead/Pin 14 BLACK lead/Pin 15 Approx. 1.1 Vdc BLACK lead/Pin 14 RED lead/Pin 15 OL DOWN depressed RED lead/Pin 14 BLACK lead/Pin 15 Approx. 1.6 Vdc BLACK lead/Pin 14 RED lead/Pin 15 OL