8 Encoder diagnostics | Diagnosis for encoders with serial interface Status bars for function reserves The status bars (1) of the Online diagnostics screen show the status of the function reserves. Up to four function reserves are supported, depending on the encoder. The following function reserves are displayed for absolute encoders with serial interfaces: Abs.Tr. : Absolute track Inc.Tr. : Incremental or scanning track Pos.Val. : Position value calculation The following function reserves are displayed for incremental encoders with purely serial interfaces: Inc.Tr. : Incremental or scanning track Ri.Width : Reference pulse width or sum Ri.Pos. : Reference pulse position Display Figure 11:
Display of the function reserves The product displays the function reserves in a bar graph: 0 % to 25 %: Yellow range Servicing/maintenance recommended 25 % to 100 %: Green range The encoder is within the specification There is a time difference of approx. 10 ms between the calculation of the position and the valuation numbers. Resetting the minimum values You can reset the minimum values displayed in the Online diagnostics screen. Tap the Refresh button The displayed minimum values are reset. HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 63