heidenhain PWT 100, PWT 101 — Resetting the drag indicators and warnings

Encoder diagnostics | Diagnostics for encoders with 1 V PP /11 µA PP /1 V PP + Z1 interface 8 Reference mark position The reference mark signal is at a specified nominal position. In the bar graph of the reference mark position, the position of the black bar indicates the deviation from the optimum position. Figure 24: Bar graph of reference mark position If certain limits are reached during the signal analysis of the encoder, for example an excessive signal frequency, the product cannot perform the signal analysis correctly. In this case, the drag indicators change and a warning symbol is shown. The drag indicators are set to the maximum values.

After the next valid measurement, the values measured so far for the drag indicators are displayed. After a certain time interval (15 s) the display is deactivated (gray). As soon as the device detects the next reference mark, the display is reactivated. Zero crossovers of reference-mark signal In the bar graph of the reference-mark zero crossovers, the positions of two black bars show the deviation of the zero crossovers of the reference mark signal from the specified values. Figure 25: Bar graph of zero crossovers of reference-mark signal After a certain time interval (15 s) the display is deactivated (gray).

As soon as the device detects the next reference mark, the display is reactivated. Resetting the drag indicators and warnings You can reset the drag indicators and warnings displayed in the PWT display screen. Tap the Refresh button The displayed drag indicators and warnings are reset. 82 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024