Industrial — 1–13. AMP MATE-N-LOK II SERIES CONNECTORS (COMPACT SHIFT SELECTOR)

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX E — CONNECTOR PART NUMBERS, TERMINAL PART NUMBERS, TOOL PART NUMBERS, AND REPAIR INSTRUCTIONS E. Terminal Crimping Using Alternate Crimper 58440-1 (Refer to Figure E–15) (cont’d) 5. Hold the terminal in position and squeeze the tool handles together until the insulation barrel anvil starts entry into the upper insert to hold the terminal in position. DO NOT deform the insulation barrel or the wire barrel. 6. Insert properly stripped wire through the wire slot in the locator until the insulation butts against the locator/insulation stop. 7.

Holding the wire in place, crimp the terminal to the wire by squeezing the tool handles together until the ratchet releases. Allow the tool handles to open FULLY and remove the wire with the crimped terminal attached. 8. Check to see if the insulation crimp is too tight or too loose. The crimp should hold the insulation firmly without cutting into it. Change the setting of the insulation adjustment lever as required. F. Terminal Insertion 1. Be sure the red wedge lock is in the open position (Figure E–14, View A). 2. Slide the wire with crimped terminal attached into the rear of the connector. 3. Push the terminal and wire into the connector until it locks into position.

Check the front of the connector to see that the terminal is at the same height as other terminals. Tug lightly on the wire (1–2 pound force) at the rear of the connector to ensure that the terminal is locked in place. NOTE: As the terminal is pushed through the wire seal it perforates the diaphragm on the seal. If an unused location is accidentally perforated, install a P/N 770678-1 Seal Plug (large end first) as shown in Figure E–14, View D. 4. After all terminals have been inserted, push inward on the wedge lock until it is flush with the connector. Squeeze inward on the connector locking latches to seat the wedge lock. NOTE: The wedge lock has slotted openings in the front or mating end.

These slots are intended to be used with circuit test tabs that are approximately 3.3 x 0.6 mm (0.130 x 0.024 inch) which prevent damage to the connector. DO NOT use a sharp point such as an ice pick! E–50 Copyright © 2001 General Motors Corp.