Industrial — APPENDIX P — INPUT/OUTPUT FUNCTIONS

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL Q. TWO-SPEED AXLE — INPUT AND OUTPUT USES: Provides output speed interlock for axle engagement, input to ECU, and input to speedometer to adjust for axle ratio change. Figure P–21. Two-Speed Axle — Input and Output Copyright © 2001 General Motors Corp. P–21 APPENDIX P — INPUT/OUTPUT FUNCTIONS WARNING! These schematics show the intended use of the specified controls features which have been validated in the configuration shown. Any miswiring or use of these features which differs from that shown could result in damage to equipment or property, personal injury, or loss of life.

ALLISON TRANSMISSION IS NOT LIABLE FOR THE CONSEQUENCES ASSOCIATED WITH MISWIRING OR UNINTENDED USE OF THESE FEATURES. VAR VOC IABLES TO SPECIFY: Output speed to activate, output speed to deactivate ATIONS: Dump truck, refuse packer, cement mixer, two-speed axle equipped vehicles OPTIONAL CUSTOMER-FURNISHED SWITCHED VIW CONNECTOR(S) POWER NOTE: If the axle actuator is an inductive load, V-12 WIRE 153 Low High it must be diode suppressed.

AXLE Axle Axle ACTUATOR TWO-SPEED V V-31 AXLE INPUT TWO-SPEED HIGH V-2 AXLE SWITCH LOW V-20 GND ECU WIRE 161 NC AUX + SIGNAL RETURN S A2 COM NO A3 SIG GND WIRE 114 TWO-SPEED F3 AXLE ENABLE WIRE SPEEDOMETER B2 H2 WIRE 157 SPEEDOMETER SIGNAL VIM 357 Relay shown de-energized V04874.01 OPTIONAL CUSTOMER-FURNISHED SWITCHED VIW CONNECTOR(S) POWER NOTE: If the axle actuator is an inductive load, V-12 WIRE 153 Low High it must be diode suppressed.

AXLE Axle Axle ACTUATOR TWO-SPEED V V-31 AXLE INPUT TWO-SPEED HIGH V-2 AXLE SWITCH LOW V-20 GND ECU WIRE 161 NC AUX + SIGNAL RETURN S A2 COM NO A3 SIG GND WIRE 114 TWO-SPEED F3 AXLE ENABLE WIRE SPEEDOMETER B2 H2 WIRE 157 SPEEDOMETER SIGNAL VIM 357 Relay shown de-energized V04874.01 V V-20