WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL AK. AUTOMATIC NEUTRAL — DUAL INPUT WITH SERVICE BRAKE STATUS — PARK BRAKE ACTIVATED USES: Provides for automatic selection of NEUTRAL and activation of PTO when park brake is applied. Automatically re-engages transmission when park brake is released (if service brake is depressed). Only re-engagement of forward is permitted. Reverse is not re-engaged. VARIABLES TO SPECIFY: Max output rpm to enable Neutral, max engine rpm for PTO engagement, max engine rpm for PTO operation, max output rpm for PTO engagement, max output rpm for PTO operation. VOCATIONS: Refuse packer, recycling truck, emergency equipment. NOTE:
This function is also available with emergency equipment calibration features. BRAKE PEDAL SWITCH Relays shown de-energized SEE NOTE * SWITCHED POWER WIRE 137 SERVICE BRAKE STATUS (Closed = Brakes On) PTO SWITCH FAST IDLE CONTROL PTO PRESSURE SWITCH WIRE 118 PTO ENABLE INPUT WIRE 161 SIGNAL RETURN F3 FAST IDLE SOLENOID WIRE 117 PACK ENABLE PRESSURE SWITCH #1 (5–20 psi) GROUND NEUTRAL INDICATOR (GREEN DASH LIGHT) Indicates neutral & park brake on NO DASH LIGHT ECU “AUTO NEUTRAL” CAB SWITCH NC COM PRESSURE SWITCH #2 (5–20 psi) SWITCHED POWER A3 PTO OPTIONAL CUSTOMER- FURNISHED VIW CONNECTOR(S) WIRE 153 AUTO NEUTRAL PACKER INPUT NO NOTE: The fast idle solenoid must be diode suppressed.
S NC COM NOTE: Transmission shifts to Neutral when both switches close (if other conditions are satisfied). Transmission shifts back to Drive when switches open, service brake switch is closed, and engine speed drops to 900 rpm within 2.5 sec. Other- wise transmission stays in Neutral. CUSTOMER SUPPLIED RELAY + Р WIRE 112 PTO ENABLE OUTPUT PARK BRAKE WIRE 114 NEUTRAL INDICATOR FOR PTO SWITCHED POWER NOTE*: Typical engine "Fast Idle" control system. Actual configuration may vary from that shown. Consult the engine manufacturer. V07130 Figure P–39. Automatic Neutral — Dual Input With Service Brake Status — Park Brake Activated P–40 Copyright © 2001 General Motors Corp.
APPENDIX P — INPUT/OUTPUT FUNCTIONS WARNING! These schematics show the intended use of the specified controls features which have been validated in the configuration shown. Any miswiring or use of these features which differs from that shown could result in damage to equipment or property, personal injury, or loss of life. ALLISON TRANSMISSION IS NOT LIABLE FOR THE CONSEQUENCES ASSOCIATED WITH MISWIRING OR UNINTENDED USE OF THESE FEATURES. V V-29 V-13 V-31 V-30 V-22 V-2 NC D2 COM NO NC A2 F3 COM NO VIM NC COM NO