WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 24 XX — SUMP FLUID TEMPERATURE (Figure 6–7) DIAGNOSTIC CODES NOTE: If using an ECU from another vehicle is unavoidable, the ECU must be set to unadapted shifts and the vehicle must be driven carefully to adapt the shifts to the test vehicle. Refer to Service Information Letter 16-WT-96 for the correct procedure. Be sure to reset the ECU to unadapted shifts when it is returned to the original vehicle. 4. If the condition persists, replace the ECU with a test diagnostic ECU (P/N must match and it is recommended that the controller be loaded with the latest version of the CIN).

If replacing the ECU corrects the problem, reinstall the original (bad) ECU to confirm that the problem is in the ECU. If the original ECU now works, inspect the ECU connectors for corrosion or damage which may cause an intermittent condition. If the original problem recurs, install a replacement ECU. Table 6–4. Transmission Operation as a Function of Temperature TEMPERATURE SENSOR CHART TEMPERATURE VS.

RESISTANCE TEMP ° C TEMP ° F OHMS 2700 2900 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 183 -58 -40 -22 -4 14 32 50 68 86 104 122 140 158 176 194 212 230 248 266 284 302 361 525 577 632 691 754 820 889 962 1039 1118 1202 1288 1379 1472 1569 1670 1774 1882 1993 2107 2225 2628 ± 7.0 ° C TEMPERATURE SENSOR RESISTANCE IN OHMS 2500 2300 ± 5.0 ° C 2100 1900 ± 4.0 ° C 1500 1700 ± 3.0 ° C 1300 ± 2.0 ° C 1100 900 ± 1.6 ° C 700 ± 3.0 ° C SUMP TEMPERATURE IN ° F LOW PT 500 4 32 68 104 140 176 212 248 284 320 356 -60 -40 --20 0 20 40 60 80 100 120 140 SUMP TEMPERATURE IN ° C 160 180 V01602.01 Figure 6–8.

TransID 1 Temperature Sensor Chart 6–40 Copyright © 2001 General Motors Corp.

Condition Version 8 Software ˚C ˚F Temperature sensor failed high (refer to code 33 23) 177 350 Hot fluid (code 24 23) — adaptive turned off; limited to 4th range or hold override upshifts beyond 4th range (not limited in “emergency” calibration) 128 262 Output function “on” for sump over temp above this temperature 121 250 Output function “off” for sump over temp below this temperature 116 240 Cool/cold fluid; adaptive turned off 34 93 Turbine reasonableness and speed tie-up tests turned off 0 32 Medium cold fluid R, N, D allowed, 2nd range start (hold override upshifts only) –7 19 All C3 Pressure Switch tests turned off –32 –25 Temperature sensor failed low (refer to code 33 12) –45 –49