139 SEBU7645-06 Maintenance Section Engine Crankcase Breather (Closed Circuit) - Replace 102356274 2. Turn the cover (1) for the filter housing counterclockwise for one quarter of a turn in order to remove the cover. Engine Crankcase Breather (Closed Circuit) - Replace (If Equipped) 3. Remove the filter element (4) by pulling the filter element out of the housing (5). SMCS Code: 1317-510-FQ 4. Clean the inside of the housing for the breather (5). S/N: DDA1-Up 5. Lubricate the O-ring (3) with clean engine oil. If S/N: RTA1-Up necessary, fit a new O-ring (3) to the housing for the breather. S/N: RBB1-Up S/N: WMB1-Up 6. Install a new filter element (4). SIN: WAC1-Up 7.
Install the cover (1) for the filter housing and turn S/N: DJD1-Up one quarter of a turn clockwise in order to lock the cover in place. S/N: WLG1-Up 8. Close all access covers. S/N: TWR1-Up S/N: DBT1-1623 101779869 S/N: TFWi-Up Engine Oil Level - Check SIN: WGX1-Up SMCS Code: 1348-535-FLV S/N: DFZ1-Up NOTICE Do not overfill the crankcase. Engine damage can result. . 1. Open the engine access door on the right side of the machine. illustration 173 00827676 (1) Breather Cap (2) (3) (4) (5) O-Ring O-Ring for the Breather Element Breather Element Housing for the Breather 1. Open the engine access door that is located on the right side of the machine. Illustration 174 go0910012 2.
While the engine is stopped, maintain the oil level in the crosshatched region of the engine oil dipstick (1). 3. If necessary, remove the oil filler plug (2) and add oil. 4. Clean the oil filler plug and install the oil filler plug. 5. Close the engine access door.