142 Maintenance Section Fuel System - Prime SEBU7645-06 g00898194 Illustration 180 Hand priming lever for the priming pump 900898197 Fuel injection nozzles in the cylinder head Note: If the drive cam of the fuel priming pump is in the position of maximum Illustration 182 cam lift, the priming lever will not operate. Rotate the crankshaft by hand one revolution. 2. Operate the priming lever on the priming pump until fuel flows out of nut (2). 3. Tighten nut (2) to a torque of 23 N-m (17 lb ft). (4) Flare nut Note: Damage to the fuel injection pump, to the battery, and to the motor starter can occur if the motor starter is used excessively to purge the air from the fuel system. 6.
Loosen flare nuts (4) for the high pressure fuel lines on two fuel injection nozzies. 7. Operate the starting motor until fuel is flowing from the fuel lines. 8. Tighten flare nuts (4) to a torque of 22 N-m (16 Ib ft). NOTICE Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again. 9. The engine is now ready to start. Operate the Illustration 181 g00905440 engine at low idle for a minimum of five minutes immediately after air has been removed from the fuel system. Air inlet heater on the air inlet manifold (3) Flare nut 4. If the fuel line for the air inlet heater has been drained, loosen nut (3).
Operate the priming lever on the fuel priming pump until fuel is free of air from the fuel line. 5. Tighten nut (3) to a torque of 22 N-m (16 lb ft). Note: Running the engine for this period of time will help ensure that the pump is completely free of air. Damage to the internal parts of the pump, which is caused by metal to metal contact, will be prevented. If the engine stops or if the engine runs roughly, check for air in the fuel system. If air is in the fuel system, leakage in the low pressure fuel system probably exists.