Komatsu — 20 Testing and adjusting

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ENGINE RELATED PARTS STANDARD VALUE TABLE FOR ENGINE RELATED PARTS fl The Standard value for new machine and Service limit value in the table below are all values when measured in the heavy-duty operation (H/O) mode. Applicable model PC130-6K + PC150LGP-6K Engine S4D102-1 SM rev. PC130/150LGP-6K 20-2 Item Measurement conditions Unit Standard value for new machine Service limit value Engine speed High idling rpm 2,000 ± 100 — Low idling 900 ± 50 — Rated speed 2,000 — Exhaust gas color At sudden acceleration At high idling Bosch index Max. 5.5 Max.

1.0 7.5 2.0 Valve clearance (normal temperaure) Intake valve Exhaust valve mm 0.25 0.51 — — Blow-by pressure (Water temperature: Operating range) At rated output (SAE30 or SAE15W-40) kPa {mmH2O} Max. 4.90 {50} 980 {100} Oil pressure (Water temperature: Operating range) At high idling (SAE30 or SAE15W-40) (SAE10W) At low idling (SAE30 or SAE15W-40) At low idling (SAE10W) kPa {kg/cm2} 343 – 686 {3.5 – 7.0} 294 – 686 {3.0 – 7.0} Min. 98 {1.0} Min. 78.4 {0.8} 245 {2.5} 206 {2.1} 69 {0.7} 69 {0.7} Oil temperature Whole speed range (inside oil pan) °C 80 – 110 120 Belt tension Deflection when pressed with finger force of approx.

58.8N {6 kg} Crankshaft pulley - air conditioner compressor mm 12 - 15 12 - 15