Komatsu — 20 Testing and adjusting

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS Applicable model PC130-6K + PC150LGP-6K SM rev. PC130/150LGP-6K 20-6 Cate- gory Item Measurement conditions Unit Standard value for new machine Service limit value Travel Travel speed (1) BKP00104 · Engine at full throttle · Hydraulic oil temperature: 45 – 55˚C · In heavy-duty operation mode · Raise track on one side at a time, rotate one turn, then measure time taken for next 5 turns with no load. Lo Sec 45.0 – 9 45.0 – 9 Mi 31.1 ± 3.1 31.1 ± 4.3 Hi 21.4 ± 2.1 21.4 ± 2.9 Travel speed (2) 45˚ BKP00105 · Engine at full throttle · Hydraulic oil temperature:

45 – 55˚C · In heavy-duty operation mode · Run up for at least 10 m, then measure time taken to travel next 20 m on flat ground. Lo PC130-6K PC150LGP-6K 27.6 ± 5.1 27.6 ± 7.1 40.6 40.6 Mi 20.3 ± 2.3 20.3 ± 3.2 25.8 25.8 Hi 13.2 ± 1.2 13.2 ± 1.7 16.0 16.0 Travel deviation 4 5 ° BKP00106 · Engine at full throttle · Hydraulic oil temperature: 45 – 55˚C · Run up for at least 10 m, then measure deviation when traveling next 20 m on flat ground. fl Use a hard horizontal surface. 20m 10m BKP00107 fl Measure dimension x. mm Max. 200 Max. 220