Lubricating Oil Cooler Assembly - Rebuild (07-11) Lubricating Oil System N14 Page 7-34 Attach a regulated air pressure hose to the other water transfer tube and apply 81 kPa [60 psi] air pressure. Caution: Conduct this test with extreme caution. Pres- surization of the oil cooler assembly while submerged in a hot water bath poses a condition where one must exercise care to avoid burns and water splash. Use heavy duty hoses and clamps for attachment of the air supply line and blanking plug to ensure against leaks and ac- cidental blanking plug expulsion during pressurization. Submerge the oil cooler in a tank of water heated to 82°C [180°F] for 3 to 5 minutes and inspect for leaks. NOTE:
If leaks are found, replace the oil cooler core. Remove the oil cooler core from the water tank. Remove the hoses and clamps from the oil cooler. Remove all water from the oil side of the cooler. Dry the oil cooler with compressed air. Testing - Oil Cooler Bypass Valve Caution: The flash point of new lubricating oil is ap- proximately 221°C [430°F]. Do not allow oil temperature in the container to exceed 149°C [300°F]. Do not allow water droplets to enter the container of hot oil. Water droplets will cause a violent reaction which can cause personal injury.