Cummins — ASSEMBLY

Lubricating Oil System Lubricating Oil Cooler Assembly - Rebuild (07-11) N14 Page 7-35 Suspend the valve and a 116°C [250°F] thermometer in a container of new lubricating oil. Do not allow the valve or the thermometer to touch the sides or bottom of the container. Heat the lubricating oil. NOTE: Record the temperature at which the valve is fully extended. The valve must be fully extended to at least 6 mm [0.250-inch] when the temperature reaches 116°C [240°F]. Replace the valve if it does not operate as described. Testing - Lubricating Oil Filter Bypass Valve Poppet Valve Spring Use the valve spring tester, Part No. 3375182, to mea- sure the spring force.

Compress the spring to a height of 59.18 mm [2.330 inch]. The force required to compress the spring to the specified height must be: MIN: 105.2 N [23.65 lbf] MAX: 123.8 N [27.85 lbf] Assembly Install straight thread o-ring plugs. Torque Value: 35 [25 ft-lb] Install Compuchek W fittings. Torque Value: 14 [10 ft-lb] Install the transfer housing support bracket. Torque Value: 45 [35 ft-lb]