Cummins — ELECTRONIC HOOKUP - CELECT ENGINES ONLY

Engine Dynamometer - Install Engine (14-01) Engine Testing N14 Page 14-16 Connect the dynamometer test OEM wiring harness start- ing motor solenoid lead (yellow) to the starting motor solenoid. Connect the ground lead (black) to the starting motor or battery negative or ground side. Connect the +12 volt DC power lead (red) to either the starting motor or battery positive (+12 volt DC) side. To control throttle input and engine speed, connect the auto/manual throttle control, Service Tool Part No. 3823828, to the throttle control leads at the keyswitch panel on the dynamometer test OEM wiring harness.

Place the ‘‘Auto-Manual’’ switch in the posi- tion to enable use of the ‘‘Min-Max RPM Adjust’’ control. Connect the keyswitch panel datalink cable to the Compulink™. Depress the ‘‘POWER button on the Compulink™. If the ‘‘Progressive Shift Feature’’ is turned it must be turned ‘‘OFF’’ during the engine test to allow the engine to accelerate through its RPM range. Select the ‘‘Adjustments’’ option from the main menu screen by depressing the number ‘‘2’’ on the Compulink™ keypad.