Cummins — LUBRICATING OIL SYSTEM PRIMING

Engine Testing Priming the Lubricating Oil and Fuel Systems (14-02) N14 Page 14-21 Disconnect the electrical wire that supplies power to the fuel pump solenoid. NOTE: The manual override screw must be turned coun- terclockwise until it stops. Caution: Do not crank the starting motor for more than 30 seconds. Excessive heat will damage the starting motor. Crank the engine until the oil pressure gauge indicates a positive pressure. NOTE: If a positive pressure is not indicated within 30 sec- onds, stop cranking the engine and allow 2 minutes for the starting motor to cool before cranking the engine again. NOTE:

If a positive oil pressure is still not indicated, find and correct the problem before continuing. Wait 10 minutes to be sure the lubricating oil has drained into the oil pan. Use the dipstick to measure the oil level. Fill the oil pan to the specified level. Use clean 15W-40 oil to lubricate the fuel filter gasket. Fill the filter with clean fuel.