Cummins — INTAKE AIR RESTRICTION

Engine Testing General Test Procedure - Chassis Dynamometer (14-05) N14 Page 14-35 Charge Air Cooler Restriction Measure the intake pressure drop across the charge air cooler. This test can be done with a mercury manometer or two separate gauges, Part No. ST-1273. If two gauges are being used, calibrate both gauges on a common pressure source at 206 kPa [30 PSI] to ensure consistency. Install one pressure gauge, Part No. ST-1273, in the fitting in the turbocharger compressor outlet elbow. In- stall the other pressure gauge in the fitting in the intake manifold. Observe the reading on the gauges. Pressure drop must not be greater than: 102 mm Hg [4.0 in. Hg] 14 kPa [2.0 psi] NOTE:

When measuring the pressure drop, operate a dy- namometer at the rpm that delivers the maximum horse- power of engine tested. Engine speed will be 1600-1700 rpm on most engines. Intake Air Restriction Measure the inlet air restriction. Install the vacuum gauge, Part No. ST-434, or a manometer in the intake air piping. NOTE: The gauge adapter must be installed at a 90 degree angle to the air flow in a straight section of pipe at a minimum of one pipe diameter before the turbocharger.