Cummins — BORE ALIGNMENT - MEASUREMENT

Engine Assembly (00-02) Flywheel Housing - Installation N14 Page 0-69 Determine the total indicator runout (T.I.R.) as follows: Example: mm in 12 o’clock 0.00 0.000 3 o’clock +0.08 +0.003 6 o’clock - 0.05 - 0.002 9 o’clock +0.08 +0.003 Equals T.I.R. 0.13 0.005 The maximum allowable total indicator runout (T.I.R.) depends on the diameter of the housing bore. See the following chart: SAE Bore Diameter Bore Location Tolerance No. mm in mm in 00 787.40 to 787.65 31.000 to 31.010 0.30 0.012 T.I.R. 0 647.70 to 647.95 25.500 to 25.510 0.25 0.010 T.I.R. 1/2 584.20 to 584.40 23.000 to 23.008 0.25 0.010 T.I.R. 1 511.18 to 511.30 20.125 to 20.130 0.20 0.008 T.I.R.

2 447.68 to 447.80 17.625 to 17.630 0.20 0.008 T.I.R. 3 409.58 to 409.70 16.125 to 16.130 0.20 0.008 T.I.R. If the bore alignment does not meet the specifications, loosen the housing capscrews. Tighten the capscrews again, and measure the bore alignment again.