Electronic control fuel injection system (Common rail type) 1E-179 DTC Flash code DTC description Item to be detected Preconditions when DTC is set DTC set condition Judgment Time Behavior when trouble occurs Diagnos is lamp Recovery from failure P1271 24 Accelerator sensor 1-2 comparison fault Difference in opening angle between accelerator sensors 1-2 is 45% or more. • Key switch input voltage is 16V or more. • DTC P1630, P1631, P1271, P1277, P1278, P1282, or P1283 is not detected. Difference in opening angle between accelerator sensors 1 and 2 is 45% or more. Approx. 3 sec. 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Back-up:
1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Does not come on. *1 P1277 Accelerator sensor 1 fault (low voltage fault) Open/short circuit/ breakage of sensor or harness • Key switch input voltage is 16V or more. • DTC P1630, P1277, or P1631 is not detected. Accelerator sensor 1 voltage is lower than 0.2 V. Approx. 1 sec. 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Back-up: 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Does not come on.
*1 P1278 Accelerator sensor 1 fault (high voltage fault) Open/short circuit/ breakage of sensor or harness • Key switch input voltage is 16V or more. • DTC P1630, P1278, or P1631 is not detected. Accelerator sensor 1 voltage is more than 4.9 V. Approx. 1 sec. 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Back-up: 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Does not come on. *1 P1282 Accelerator sensor 2 fault (low voltage fault) Open/short circuit/ breakage of sensor or harness • Key switch input voltage is 16V or more. • DTC P1630, P1282, or P1631 is not detected.
Accelerator sensor 2 voltage is lower than 0.2 V. Approx. 1 sec. 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Back-up: 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Does not come on. *1 P1283 Accelerator sensor 2 fault (high voltage fault) Open/short circuit/ breakage of sensor or harness • Key switch input voltage is 16V or more. • DTC P1630, P1283, or P1631 is not detected. Accelerator sensor 2 voltage is more than 4.9 V. Approx. 1 sec. 1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Back-up:
1 system fault...No back-up 2 system fault...Accelerator opening angle is controlled to 0%. Does not come on. *1