Electronic control fuel injection system (Common rail type) 1E-181 DTC Flash code DTC description Item to be detected Preconditions when DTC is set DTC set condition Judgment Time Behavior when trouble occurs Diagnos is lamp Recovery from failure P1631 55 Voltage fault in 5-V power supply 1 Power supply wiring short to sensor, or breakage in element/ circuit for power supply regulation inside ECM. • DTC P1630 is not detected. • Key switch input power supply voltage is between 16 — 32 V. 5-V 1 power supply voltage is 5.5 V or more, or 4.5 V or less. Approx. 0.5 sec. Accelerator opening angle is controlled to 0%. Back-up:
Same to accelerator sensor fault ON *2 P1632 Voltage fault in 5-V power supply 2 • DTC P1630 is not detected. • Key switch input power supply voltage is between 16 — 32 V. 5-V 2 power supply voltage is 5.5 V or more, or 4.5 V or less. Approx. 0.5 sec. Due to back-up equivalent to 2500m (8200ft) • Black smoke emitted at high altitude • Output lowers at low altitude Back-up: Same to barometric pressure and intake air temperature sensor fault ON *2 P1633 Voltage fault in 5-V power supply 3 • DTC P1630 is not detected. • Key switch input power supply voltage is between 16 — 32 V. 5-V 3 power supply voltage is 5.5 V or more, or 4.5 V or less. Approx. 0.5 sec.
Deterioration of startability, black smoke emission possible Operationality is affected. Back-up: Same to oil pressure, coolant temperature, and combustion temperature sensor fault ON *2 P1634 Voltage fault in 5-V power supply 4 • DTC P1630 is not detected. • Key switch input power supply voltage is between 16 — 32 V. 5-V 4 power supply voltage is 5.5 V or more, or 4.5 V or less. Approx. 0.5 sec. Operationality is affected. Back-up: Specified back-up value ON *2 P1635 Voltage fault in 5-V power supply 5 • DTC P1630 is not detected. • Key switch input power supply voltage is between 16 — 32 V. 5-V 5 power supply voltage is 5.5 V or more, or 4.5 V or less. Approx. 0.5 sec.
Engine blow up, output lowering, black smoke emission, engine stall are possible. Back-up: Same to rail pressure sensor fault and EGR position sensor fault ON *2 U2104 84 CAN Bus fault CAN communicati on fault • Key switch input voltage is 12V or more. Bus-off is detected. At 3 sec. continuous ly Vary depending on setting. Back-up: Specified back-up value ON *3 U2106 85 CAN timeout fault CAN communicati on fault • DTC U2104 is not detected. • Key switch input voltage is 12V or more. CAN data reception does not complete at a set time. At 1 sec. continuous ly Vary depending on setting. Back-up: Specified back-up value ON *3