hitachi — DTC: P0092/P1292 (Flash code 217/218) PCV circuit fault (PCV1+B short circuit / PCV2+B short circuit / PCV2+B short circuit)

1E-200 Electronic control fuel injection system (Common rail type) Back-up mode Diagnostic aid P0092: PCV1 stop P1292: PCV2 stop If the intermittent trouble is suspected, followings may be the cause. Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage.

Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part. Recovery from failure Refer to “List of diagnostic trouble code” and “About recovery from failure” in this section for recovery from failure. The conditions to clear the MIL/DTC The present trouble turns to history trouble when the condition is out of the range from DTC set condition (recovery from failure). The diagnosis lamp will go off after the code turns to history trouble and the key switch is turned “OFF” then “ON” again.

Using the scan tool, or memory clear switch and diagnostic switch operation enables to clear DTCs. Step Action Value YES NO 1 Perform the OBD system check. Is the procedure completed? — Go to Step 2. Go to “OBD system check”. 2 1. Check for followings in the circuit between PCV and ECM using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. • Short circuit to power supply circuit or ignition power supply circuit • Short circuit to other signal circuit 2. If the trouble is detected, repair or replace as required. Is the trouble detected? — Go to Step 9. Go to Step 3. 3 Check the PCV body.

1. Turn the key switch to “OFF”. 2. Remove the harness from the PCV. 3. Measure the resistance between the PCV connector terminals. Is the resistance specified value? Between terminals: 3.2±0.3 Ω; Each terminal to PCV body: ∞Ω (at normal temperature) Go to Step 5. Go to Step 4. 4 Replace the supply pump (PCV). Note: For work procedure, refer to “Engine section” in the service manual. Is the procedure completed? — Go to Step 9. —