1E-344 Electronic control fuel injection system (Common rail type) The conditions to clear the MIL/DTC Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage. Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part. The present trouble turns to history trouble when the condition is out of the range from DTC set condition (recovery from failure). The diagnosis lamp turns off when the trouble code turns to the history trouble.
Using the scan tool, or accelerator pedal operation enables to clear history trouble. Diagnostic aid If the intermittent trouble is suspected, followings may be the cause. Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Test description Numbers below indicate step numbers in the chart. 6. If the “Glow relay” displays “ON” when terminals between the glow relay are shorted, the circuit beyond the relay is normal including ECM. 9.
If the “Glow relay” displays “OFF” when the glow relay is removed, the circuit beyond the relay is normal including ECM. Step Action Value YES NO 1 Perform the OBD system check. Is the procedure completed? — Go to Step 2. Go to “OBD system check”. 2 Is the scan tool (KW communication) available? — Go to Step 3. Go to Step 17. 3 1. Turn the key switch to ON position. 2. Check for “Glow relay” on the data display using scan tool. Is the “Glow relay” displayed “ON”? — Go to Step 4. Go to Step 5. 4 1. Turn the key switch to ON position. 2. Hold it for more than 10 seconds. 3. Check for “Glow relay” on the data display using scan tool. Is the “Glow relay” displayed “OFF”?
— Go to “Diagnostic aid”. Go to Step 9. 5 Check for installation condition of the glow relay, ECM connector and coupling connector. 1. Check for play or looseness in the connection. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 12. Go to Step 6. 6 1. Turn the key switch to “OFF”. 2. Remove the glow relay. 3. Short between the terminals 2 - 4 in the glow relay installing portion using jump cable. 4. Turn the key switch to “ON”. 5. Check for “Glow relay” on the data display using scan tool. Is the “Glow relay” displayed “ON”? — Go to Step 11. Go to Step 7.