1E-394 Electronic control fuel injection system (Common rail type) Step Action Value YES NO 10 1. Check for followings in the circuit between the ST terminal of the key switch and the ECM using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. • Open circuit • Short circuit to ground circuit • High resistance 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 17. Go to Step 14. 11 1. Turn the key switch to “OFF”. 2. Remove the starter cut relay. 3. Connect the DMM between the starter cut relay drive terminal of the ECM and the ground. 4.
Turn the key switch to “ON”. Is the DMM indication less than the specified value? 0V Go to Step 13. Go to Step 12. 12 1. Check the circuit between starter cut relay and ECM for short circuit to the power supply circuit or ignition power supply circuit using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 13. Go to Step 14. 13 Replace the starter cut relay. Is the procedure completed? — Go to Step 17. — 14 Is EMPS available? — Go to Step 15. Go to Step 16.