hitachi — DTC: P1112 (Flash code 295) Boost temperature sensor fault (low voltage fault, ground short)

1E-430 Electronic control fuel injection system (Common rail type) Recovery from failure Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage. Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part.

Refer to “List of diagnostic trouble code” and “About recovery from failure” in this section for recovery from failure. The conditions to clear the MIL/DTC The present trouble turns to history trouble when the condition is out of the range from DTC set condition (recovery from failure). The diagnosis lamp will go off after the code turns to history trouble and the key switch is turned “OFF” then “ON” again. Using the scan tool, or memory clear switch and diagnostic switch operation enables to clear DTCs. Diagnostic aid Test description If the intermittent trouble is suspected, followings may be the cause.

Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding Numbers below indicate step numbers in the chart. 3. In the case of present trouble, the “Boost temperature sensor” displays less than the specified value. If more than the specified value, identify the cause by referring to “Diagnostic aid”. 5. If the “Boost temperature sensor” displays more than the specified value when terminals between the boost temperature sensor connector are shorted, the circuit beyond the sensor is normal including ECM. Step Action Value YES NO 1 Perform the OBD system check. Is the procedure completed? — Go to Step 2.

Go to “OBD system check”. 2 Is the scan tool (KW communication) available? — Go to Step 3. Go to Step 13. 3 1. Turn the key switch to “ON”. 2. Check for “Boost temperature sensor” on the data display using scan tool. Is the “Boost temperature sensor” less than the specified value? 0.1V Go to Step 4. Go to “Diagnostic aid”. 4 Check for installation condition of the boost temperature sensor connector, ECM connector and coupling connector. 1. Check for play or looseness in the connection. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 12. Go to Step 5.