hitachi — DTC: P1112 (Flash code 295) Boost temperature sensor fault (low voltage fault, ground short)

Electronic control fuel injection system (Common rail type) 1E-431 Step Action Value YES NO 5 1. Turn the key switch to “OFF”. 2. Disconnect the boost temperature sensor connector. 3. Short between the boost temperature sensor connector ground terminal and the signal terminal using jump cable. 4. Turn the key switch to “ON”. 5. Check for “Boost temperature” on the data display using scan tool. Is the “Boost temperature” more than the specified value? 4.8V Go to Step 8. Go to Step 9. 6 1. Check for followings in the power supply circuit between ECM and boost temperature sensor, using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note:

If breaker box is not available, refer to “On- board check procedure for sensors”. • Open circuit • High resistance 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 12. Go to Step 7. 7 1. Check for followings in the signal circuit between ECM and boost temperature sensor, using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. • Short circuit to boost temperature sensor ground circuit • Short circuit to ground • Open circuit • High resistance 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 12. Go to Step 9.

8 Replace the boost temperature sensor. Is the procedure completed? — Go to Step 12. — 9 Is EMPS available? — Go to Step 10. Go to Step 11.