Electronic control fuel injection system (Common rail type) 1E-533 Breaker box inspection procedure Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. Name 1. Breaker box 2. DMM Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 8 Short circuit to power supply circuit Voltage measurement • Remove all the relevant ECU connectors. • Key switch “ON” 18 - Ground 37 - Ground 0V 18V or more 9 Open circuit/ high resistance Resistance measurement • Remove all the relevant ECU connectors.
• Key switch “OFF” 37 - Machine control unit 18 - Machine control unit 100Ω or less 10 MΩ or more Short circuit to ground Resistance measurement • Remove all the relevant ECU connectors. • Key switch “OFF” 18 - Ground 37 - Ground 10 MΩ or more 100 Ω or less