Kaiyi — Kaiyi Hydraulic Systems Maintenance Manual

3. TEST TOOLS 3. TEST TOOLS CLAMP-ON ELECTRONIC TACHOMETER CLAMP-ON ELECTRONIC TACHOMETER INSTALLATION INSTALLATION В Service equipment and tools Tachometer A : Clamp on tachometer. Remove paint using emery cloth and connect to a straight section of injection line within 100 mm (4 in ) of pump. Finger Tighten only-do not over tighten. B : Black clip ( - ). Connect to main frame. C : Red clip (+). Connect to transducer. D : Tachometer readout. Install cable. 1) B C D A 75795SE32 2) DIGITAL THERMOMETER INSTALLATION DIGITAL THERMOMETER INSTALLATION В Service equipment and tools Digital thermometer A : Temperature probe. Fasten to a bare metal line using a tie band. Wrap with shop towel. B :

Cable. C : Digital thermometer. A C B 75795SE33 3) DISPLAY MONITOR TACHOMETER DISPLAY MONITOR TACHOMETER The display monitor tachometer is accurate enough for test work. 7609A5SE35 6-54