Kaiyi — Kaiyi Hydraulic Systems Maintenance Manual

6. L 6. LO ADER SYSTEM AND PORT RELIEF ADER SYSTEM AND PORT RELIEF VALVE PRESSURE TEST VALVE PRESSURE TEST В SPECIFICATION SPECIFICATION Oil temperature (40~50 C) U M LS relief valve W D T P В Gauge and tool Gauge 0~35 MPa (0~350 bar , 0~5000 psi ) M : System (main) relief valve R : Bucket rollback relief D : Bucket dump relief U : Boom raise relief R Pressure measure positon : MCV P port 1) Install fitting and pressure gauge to test port in pump delivery line. 2) Install temperature reader. (see temperature reader installation procedure in this group) P 3) Heat hydraulic oil to specifications.

(see hydraulic oil warm up procedure in this group) MCV 4) To check the system relief (M), run engine at high idle. Lower boom to bottomed position. Slowly activate boom down function while watching pressure gauge. If pressure is not to specification, loosen lock nut on system relief valve (M) and adjust to specification. Do not adjust the system relief valve above 280 kg/cm 2 (3980 psi ). Damage to the pump will result from excessive pressure settings.

Main pump Hyd tank 侍 760F6WE28 6-57 Relief valve Engine speed Relief pressure System (M) LS relief valve High 280Ü5 kg/cm2 (3980Ü70 psi) Boom raise (U) Low 340Ü10 kg/cm2 (4840Ü140 psi) Boom down (W) Bucket Low 340Ü10 kg/cm2 (4840Ü140 psi) 340Ü10 kg/cm2 rollback (R) Bucket dump (D) Low Low (4840Ü140 psi) 300Ü10 kg/cm2 (4270Ü140 psi)