7. HYDRAULIC SYSTEM RESTRICTION TEST 7. HYDRAULIC SYSTEM RESTRICTION TEST SPECIFICATION SPECIFICATION Oil temperature 45 Ь 5 C (113 Ь 9 F) Engine speed High idle Maximum pressure 4.5 MPa (45 bar , 640 psi ) at steering valve (EHPS). Maximum pressure at main control valve 1 MPa (10 bar , 145 psi ) GAUGE AND TOOL GAUGE AND TOOL Gauge 0~7 MPa (0~70 bar , 0~1000 psi ) 2EA This test will check for restrictions in the hydraulic system which can cause overheating of hydraulic oil. В В P 1) Install temperature reader. (see temperature reader installation procedure in this group) Steering valve(EHPS) 2) Heat hydraulic oil to specifications.
(see hydraulic oil warm up procedure in this group) 3) Connect fitting and gauge to steering valve. 4) Connect fitting and gauge to main control valve. Do not operate steering or loader funct-ions Do not operate steering or loader funct-ions or test gauge may be damaged. or test gauge may be damaged. 5) Run engine at specification and read pressure gauges. T If pressure is more than specification at the loader control valve, check for a kinked, dented or obstructed hydraulic line. Check loader control valve for a binding spool. MCV If pressure is more than specification at the steering unit, inspect neutral condition of the steering unit and steering valve for a stuck spool.
Make sure orifice plugs are installed in ends of priority valve spool. Check for plugged orifice in priority valve and dynamic signal orifice on steering valve body. Hyd tank Main pump 760F6WE39 6-58