SEBU8726-03 89 Maintenance Section Battery Electrolyte Level - Check Note: Always recycle a battery. Never discard a battery. Dispose of used batteries to an appropriate recycling facility. Thoroughly rinse the battery case with clean water. i02323088 Battery or Battery Cable - Disconnect 6. Remove the used battery. 7. Install the new battery. Note: Before the cables are connected, ensure that the battery disconnect switch is in the OFF position. 8. Connect the POSITIVE + cable to the POSITIVE + battery terminal. 9. Connect the NEGATIVE - cable to the NEGATIVE - battery terminal. The battery cables or the batteries should not be removed with the battery cover in place.
The bat- tery cover should be removed before any servic- ing is attempted. 10. Turn the battery disconnect switch to the ON position. Removing the battery cables or the batteries with the cover in place may cause a battery explosion resulting in personal injury. i02747977 Battery Electrolyte Level - Check 1. Turn the start switch to the OFF position. Turn the ignition switch (if equipped) to the OFF position and remove the key and all electrical loads. When the engine is not run for long periods of time or when the engine is run for short periods, the batteries may not fully recharge. Ensure a full charge in order to help prevent the battery from freezing.
If batteries are correctly charged, the ammeter reading should be very near zero, when the engine is in operation. 2. Disconnect the negative battery terminal. Ensure that the cable cannot contact the terminal. When four 12 volt batteries are involved, two negative connection must be disconnected. 3. Remove the positive connection. 4. Clean all disconnected connection and battery terminals. All lead-acid batteries contain sulfuric acid which can burn the skin and clothing. Always wear a face shield and protective clothing when working on or near batteries. 5. Use a fine grade of sandpaper to clean the terminals and the cable clamps. Clean the items until the surfaces are bright or shiny.
DO NOT remove material excessively. Excessive removal of material can cause the clamps to not fit correctly. Coat the clamps and the terminals with a suitable silicone lubricant or petroleum jelly. 1. Remove the filler caps. Maintain the electrolyte level to the FULL mark on the battery. If the addition of water is necessary, use distilled water. If distilled water is not available use clean water that is low in minerals. Do not use artificially softened water. 6. Tape the cable connections in order to help prevent accidental starting. 7. Proceed with necessary system repairs. 2. Check the condition of the electrolyte with a suitable battery tester. 8.
In order to connect the battery, connect the positive connection before the negative connector. 3. Install the caps. 4. Keep the batteries clean. Clean the battery case with one of the following cleaning solutions: Use a solution of 0.1 kg (0.2 lb) baking soda and 1 L (1 qt) of clean water. Use a solution of ammonium hydroxide.