Perkins — Perkins 854E-E34TA and 854F-E34T Industrial Engines Operation and Maintenance Manual

SEBU8726-03 91 Maintenance Section Coolant (ELC) - Change 3. Fill the cooling system with clean water. Install the cooling system filler cap. 4. Start and run the engine at low idle until the temperature reaches 49 to 66 °C (120 to 150 °F). 5. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Remove the drain plug on the engine. Open the drain cock or remove the drain plug on the radiator. Allow the water to drain. Flush the cooling system with clean water. Fill 1. Install the drain plug on the engine. Close the drain cock or install the drain plug on the radiator.

NOTICE Do not fill the cooling system faster than 5 L (1.3 US gal) per minute, in order to avoid air locks. Cooling system air locks may result in engine damage. Illustration 48 g02590196 Filler cap 5. Clean the cooling system filler cap and inspect the gasket. If the gasket is damaged, discard the old filler cap and install a new filler cap. If the gasket is not damaged, use a suitable pressurizing pump in order to pressure test the filler cap. The correct pressure is stamped on the face of the filler cap. If the filler cap does not retain the correct pressure, install a new filler cap. 2. Fill the cooling system with Commercial Heavy- Duty Coolant.

Add Supplemental Coolant Additive to the coolant. For the correct amount, refer to the Operation and Maintenance Manual, “Fluid Recommendations” topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap. 3. Start and run the engine at low idle. Increase the engine rpm to high idle. Operate the engine in order to open the engine thermostat. This operation will allow any air in the system to be purged. Decrease the engine speed to low idle. Stop the engine. 6. Start the engine. Inspect the cooling system for leaks and for correct operating temperature. i05944034 Coolant (ELC) - Change 4.

Maintain the coolant level at the maximum mark that is correct for your application. NOTICE Care must be taken to ensure that fluids are con- tained during performance of inspection, mainte- nance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable contain- ers before opening any compartment or disassem- bling any component containing fluids. Dispose of all fluids according to Local regulations and mandates. NOTICE Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life.