Perkins — Perkins 854E-E34TA and 854F-E34T Industrial Engines Operation and Maintenance Manual

92 SEBU8726-03 Maintenance Section Coolant (ELC) - Change Clean the cooling system and flush the cooling system before the recommended maintenance interval if the following conditions exist: The engine overheats frequently. Foaming of the coolant is observed. The oil has entered the cooling system and the coolant is contaminated. The fuel has entered the cooling system and the coolant is contaminated. Note: When the cooling system is cleaned, only clean water is needed when the ELC is drained and replaced. Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained.

This inspection can be a good opportunity to replace the water pump, the water temperature regulator, and the hoses, if necessary. NOTICE When any servicing or repair of the engine cooling system is performed, the procedure must be per- formed with the engine on level ground. Level ground will allow you to check accurately the coolant level. This check will also help in avoiding the risk of intro- ducing an air lock into the coolant system. Illustration 49 g02513896 Typical example 2. Remove the drain plug (1) on the engine. Also, open the drain cock or remove the drain plug on the radiator. Allow the coolant to drain. Drain Pressurized System: Hot coolant can cause seri- ous burns.

To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure. 1. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Illustration 50 g03732615 3. For radiators installed by the engine manufacturer, remove the drain plug (2) from radiator (3) and allow coolant to drain. After the system has been flushed, install the drain plug to a torque of 6 N·m (53 lb in).