SEBU8726-03 93 Maintenance Section Coolant Extender (ELC) - Add NOTICE Dispose of used engine coolant or recycle. Various methods have been proposed to reclaim used cool- ant for reuse in engine cooling systems. The full distil- lation procedure is the only method acceptable by Perkins to reclaim the coolant. 4. Maintain the coolant level at the maximum mark that is correct for your application. For information regarding the disposal and the recycling of used coolant, consult your Perkins distributor. Flush 1. Flush the cooling system with clean water in order to remove any debris. 2. Install the drain plug in the engine. Close the drain cock or install the drain plug on the radiator. 3.
Fill the cooling system with clean water. Install the cooling system filler cap. 4. Start and run the engine at low idle until the temperature reaches 49 to 66 °C (120 to 150 °F). 5. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Remove the drain plug on the engine. Open the drain cock or remove the drain plug on the radiator. Allow the water to drain. Flush the cooling system with clean water. Illustration 51 g02590196 Filler cap 5. Clean the cooling system filler cap and inspect the gasket. If the gasket is damaged, discard the old filler cap and install a new filler cap.
If the gasket is not damaged, use a suitable pressurizing pump in order to pressure test the filler cap. The correct pressure is stamped on the face of the filler cap. If the filler cap does not retain the correct pressure, install a new filler cap. Fill 1. Install the drain plug on the engine. Close the drain cock or install the drain plug on the radiator. 6. Start the engine. Inspect the cooling system for leaks and for correct operating temperature. NOTICE Do not fill the cooling system faster than 5 L (1.3 US gal) per minute, in order to avoid air locks. i05197396 Coolant Extender (ELC) - Add Cooling system air locks may result in engine damage. 2.
Fill the cooling system with Extended Life Coolant (ELC). Refer to the Operation and Maintenance Manual, “Fluid Recommendations” topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap. In order for Perkins ELC to achieve 12000 hours an extender must be added at 6000 hours. For a suitable extender, contact your Perkins dealer or Perkins distributor. 3. Start and run the engine at low idle. Increase the engine rpm to high idle. Operate the engine in order to open the engine thermostat. This procedure will allow any air in the system to be purged. Decrease the engine speed to low idle. Stop the engine.