MAINTENANCE PROCEDURE MAINTENANCE 4. Return the key in starting switch (3) to the ON position and leave for 30 seconds. 5. Turn the key in starting switch (3) again to the START position and hold for 20 seconds. When doing this, the starting motor will turn for approx. 2 seconds and then stop, but the engine is running. Even the engine is running, keep key (3), in the starting switch at the START position. When the starting switch is at the START position, the electric pump actuates to bleed the air. NOTICE Keep starting switch key (3) at the START position for 20 seconds to bleed the air. If starting switch key (3) is turned to the ON position, the air bleeding is not completed. 6.
Turn starting switch key (3) to the ON position. If the engine fails to rotate, repeat Step 5. NOTICE When the engine stops because of running out of fuel, add fuel to the tank until full and carry out the same procedure 2 or 3 times to bleed the air. 4-64