Crankshaft, Main Bearings and Flywheel/Remove and Clean Piston Cooling Orifices INSPECT THRUST BEARINGS 1. Check thrust surfaces of the thrust bearing and the thrust bearing journal on crankshaft and replace as necessary. Thrust bearings are available in each of the previously mentioned insert undersizes. An oversize thrust washer set containing one regular size washer and two 0.18 mm (0.007 in.) oversize washers is also available. R24545 -UN-15DEC88 NOTE: Thrust bearings must be installed with slots facing crankshaft flange. Two halves (A) and (C) go on cap side, not block.
A—Lower Rear Thrust Washer B—Upper Rear Thrust Washer C—Lower Front Thrust Washer D—Main Bearing Block Thrust Bearing E—Main Bearing Cap Thrust Bearing F—Large Tang G—Small Tang S11,0403,AF -19-08MAR94 15 40 REMOVE AND CLEAN PISTON COOLING ORIFICES 1. Remove all six piston cooling orifices (A) and inspect each cooling orifice to make sure it is not plugged or damaged. 2. Use a soft wire and compressed air to clean orifice. Replace, if condition is questionable. IMPORTANT: A piston cooling orifice failure could cause damage to pistons, piston pins, rod pin bushings, and liners. If a piston cooling orifice is left out, low or no oil pressure will result. 3.
Install orifices and tighten to 11 N·m (8 lb-ft) (96 lb-in.). RG5811 -UN-12AUG91 CTM42 (24MAR95) 15-40 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,G15,20-19-29OCT92 160101 PN=169