John Deere 400 6076 — John Deere 400 6076 User Manual

Crankshaft, Main Bearings and Flywheel/Check Oil Seal Housing Runout CHECK OIL SEAL HOUSING RUNOUT IMPORTANT: On service “short block” assemblies, rear oil seal housing runout is preset at the factory. Do not remove housing from block. 1. Position magnetic base dial indicator (A) on end of crankshaft flange as shown. Preset dial indicator tip on ID of oil seal housing bore (B). 2. Zero dial indicator and rotate crankshaft one full revolution, observe full indicator movement. The maximum oil seal housing bore runout is 0.15 mm (0.006 in.).

RG5751 -UN-05AUG91 If runout exceeds specification, loosen cap screws and adjust housing to obtain an acceptable runout while keeping bottom of seal housing flush with oil pan mating surface. 3. Recheck oil seal housing bore runout. If runout still exceeds specification, oil seal housing bore is possibly distorted and should be replaced. See INSTALL CRANKSHAFT REAR OIL SEAL HOUSING, earlier in this group. 15 45 S11,2515,AK -19-16AUG94 CTM42 (24MAR95) 15-45 6076 Diesel Engines—S.N. (500000— ) 160101 PN=174