Cooling System/Water Manifold Mounted Fixed Fan Drive Assembly RG6437 -UN-13OCT92 A—Water Manifold C—Bearing E—Hub* B—Fan Pulley D—Bearing Shaft Installed Dimension • To Assemble Fan Drive: (1.311—1.318 in.) (D) from manifold mounting surface. Hold water manifold firmly and turn fan pulley by hand to assure bearings rotate freely. IMPORTANT:Support water manifold on machined surface and press on inner shaft to prevent damage to bearing. 3. Install a new gasket and O-rings. Insert water bypass pipe in manifold and install assembly onto locating pin in front face of cylinder head. Tighten cap screws to 60 N·m 45 (lb-ft). 1.
On units with a press-fit fan spacer, press spacer into pulley flush to 0.5 mm (0.020 in.) below front face of pulley. 2. Press bearing shaft (C) into water manifold (A). End of shaft should be 33.31—33.47 mm 4. Install fan and V-belts. Refer to appropriate operator’s manual for proper belt tensioning. 25 11 *In some applications, bearing is pressed into hub (E). The fan spacer and pulley are then bolted to hub. In some applications, the fan spacer is press-fitinto the pulley. Dimension (D) is the same for all applications. RG,CTM42,G25,48-19-22MAR95 CTM42 (24MAR95) 25-11 6076 Diesel Engines—S.N. (500000— ) 160101 PN=230