Fuel System/Inspect and Repair Mechanical Fuel Supply Pump (Robert Bosch) 6. Push inlet valve (B) and seal (C) out of plunger (A) by poking rounded end of a small pin through closed end of plunger. NOTE: The outlet valve is located in outlet valve fitting (D) and is not removable from fitting. RG5913 -UN-28AUG91 A—Plunger B—Inlet Valve Seal C—Inlet Valve D—Outlet Valve and Fitting RG,CTM42,G35,65-19-03OCT92 INSPECT AND REPAIR MECHANICAL (FLAT PLUNGER) FUEL SUPPLY PUMP—ROBERT BOSCH 1. Inspect supply pump housing (C) for cracks and wear. Be sure plunger bore is not worn or scored. Check condition of threads for inlet and outlet fittings, hand primer pump, and spindle guide plug (H).

RG5912 -UN-28AUG91 2. Inspect spindle (I) for wear, scoring on OD, and burrs. Check lands that contact plunger and fuel pump cam lobe to be sure they are flat and undamaged. Remove any deposits with a suitable solvent. 3. Inspect plunger (F) for burrs and pits. Remove any A—Outlet Valve Fitting B—O-Ring deposits with a suitable solvent. C—Supply Pump Housing D—Spring Wear Plates 4. Inspect spring (E) and wear plates (D) for cracks, E—Spring distortion, and wear. F—Plunger Assembly G—O-Ring H—Spindle Guide Plug 5. Inspect inlet valve and seal (not shown) for wear, I—Spindle cracks, and broken or missing spring. J—O-Ring 6.

Inspect outlet valve and fitting (A) for wear, cracks, broken or missing spring, or damaged threads. If any of the above parts are damaged, worn, or defective, replace as necessary. 35 17 RG,CTM42,G35,66-19-14FEB95 CTM42 (24MAR95) 35-17 6076 Diesel Engines—S.N. (500000— ) 160101 PN=294