Fuel System Operation and Test/Check Mechanical Fuel Supply Pump Operation CHECK MECHANCIAL FUEL SUPPLY PUMP OPERATION NOTE: The following test procedures can best be performed under moderate air temperature conditions to reduce electrical loads when cranking the engine is required. RG5903 -UN-19AUG91 115 20 • Test fuel supply pump and hand primer for leaks: 1. Make a preliminary inspection of supply pump. Thoroughly clean area around pump. All connections must be tight and not leaking. 2. Start engine and bring to operating temperature. Shut-off engine. NOTE: If fuel leaks around a Nippondenso hand primer that is screwed down tight when engine is running, replace the hand primer.
Robert Bosch hand primers (A) are spring loaded to remain in the fully extended position. If fuel leaks around a Bosch hand primer while seated in the extended position, replace the hand primer. 3. Check operation of hand primer. With engine shut-off, unscrew knob (Nippondenso only) and operate hand primer through several strokes. Moderate to heavy leakage of fuel between plunger and barrel indicates seal is defective. Replace hand primer. NOTE: Appearance of a slight quantity of fuel around the plunger is normal. IMPORTANT: On Nippondenso pumps, be sure hand primer is seated all the way down in barrel before tightening to prevent internal thread damage. 4.
On Nippondenso pumps only, tighten hand primer knob, but do not overtighten. If knob will not tighten (indicating internal thread damage), replace hand primer. CTM42 (24MAR95) 115-20 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,115,6 -19-17MAR95 160101 PN=403