Fuel System Operation and Test/Test Electric Fuel Supply Pump Output Pressure and Flow FUEL SHUT-OFF SOLENOID OPERATIONAL CHECK RW19612 -UN-04DEC91 RW19613 -UN-04DEC91 1. Observe fuel shut-off lever (A) when key switch is turned from “OFF” to “START” (engine running at slow idle) and then released to “ON” position. 115 26 2. Fuel shut-off lever should move from “NO FUEL” position (B) to “RUN” position (C) when starting motor begins to crank. The lever should remain at the “RUN” position after key switch is released to “ON” position. If fuel shut-off lever returns to “NO FUEL” position with key switch at “ON” position, check for: —Loss of battery voltage to fuel shutoff winding.
Check voltage and wiring connection to solenoid. —Binding of fuel shut-off lever, solenoid rod or linkage does not allow solenoid to lock in position. Repair or replace linkage. —Torn or leaking rubber boot allowing dirt or moisture to enter at spring end of solenoid rod. —Improperly adjusted fuel shut-off solenoid linkage. See FUEL SHUT-OFF SOLENOID LINKAGE ADJUSTMENT, later in this group. 3. Start engine and run at slow idle. Turn key switch to “OFF” position. 4. Fuel shut-off lever should move to “NO FUEL” position and engine should stop. If the solenoid stops just short of the “NO FUEL” position, slight adjustment of the linkage is required.
See FUEL SHUT-OFF SOLENOID LINKAGE ADJUSTMENT, later in this group. If engine continues to run with key switch at “OFF” position, unplug shut-off solenoid 3-way connector. —If solenoid moves lever to “NO FUEL” position, problem is in the electrical circuit. —If solenoid does not shut off fuel to engine, check linkage for binding or excessive tightness. Replacement service kit is available with a swivel rod which is less sensitive to misalignment and binding. CTM42 (24MAR95) 115-26 6076 Diesel Engines—S.N. (500000— ) RG,CTM61,115,29-19-13MAY93 160101 PN=409