Cylinder Head and Valves/Inspect and Clean Ventilator Outlet Hose 4. Clean threads with heavy foreign deposits or clean up damaged threads using the JDF5 Tap (M28 x 1.5 mm) or an equivalent M28 x 1.5 mm (metric) tap (A). Be sure to start tap straight to avoid possible cross-threading. A light coat of grease on tap will help collect foreign deposits on tap and prevent them from falling into the nozzle bore. RG5252 -UN-06DEC88 RG,CTM42,G5,15 -19-22AUG91 5. Clean nozzle seating surface by using the JDG609 Nozzle Seat Reamer (A) to remove carbon. 6. Blow out debris with compressed air and thoroughly clean all nozzle bores.
05 28 RG5253 -UN-06DEC88 S11,2005,NU -19-23AUG91 CLEAN AND INSPECT PUSH RODS 1. Clean push rods with solvent and compressed air. 2. Check push rods for straightness by rolling on a flat surface. T81233 -UN-01NOV88 3. Inspect contact ends for wear and damage. 4. Replace defective push rods. S11,2005,JN -19-24APR92 INSPECT AND CLEAN VENTILATOR OUTLET HOSE 1. Check ventilator outlet hose (A) on rocker arm cover for bent or damaged condition. Replace if necessary. RG5797 -UN-12AUG91 2. Clean ventilator hose if restricted. CTM42 (24MAR95) 05-28 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,G5,9 -19-28OCT92 160101 PN=71