Komatsu — 24.7 EVERY 2000 HOURS SERVICE

24. SERVICE PROCEDURE 24.7.4 REPLACE PPC (PROPORTIONAL PRESSURE CONTROL) FILTER ELEMENT l When removing oil filler cap 0, turn it slowly to re- l When loosening bolt 0, turn it slowly to release the NOTICE l If there is oil in the tank, the oil will overflow, so drain the hydraulic oil before carrying out this operation. For details, see 24.7.1 CHANGE OIL IN HYDRAULIC TANK, REPLACE HYDRAULIC FILTER ELEMENT, AND CLEAN STRAINER. Release the pressure in the accumulator circuit before re- placing the element. After stopping the engine, set safety locks 0 to the FREE position, then operate each work equipment control lever @ 3 or 4 times to the end of its stroke.

The remaining pressure in the accumulator circuit will be released after one minute. l 1. 2. 3. Remove oil filler cap 0 of the hydraulic tank. Open the inspection cover in the middle of the floor. Loosen bolt 0, remove bolts 0 and filter cover 0, then take out spring 0, valve 0, and element 8. 4. Wash the parts that have been removed, then fit a new element and install all the parts again. Replace the O-ring at the same time. Close the inspection cover. 5. 3-66